ETC Request ID: STIS.sp.926199

Requested Signal/Noise Ratio = 10.000 at wavelength 1300.00 Å (per resolution element)

gives: Time = 5,650.4958 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x pix) (2.0 pix resel x pix)
    Source 0.012 134.26 11.59
    Background 0.001 11.87 3.44
        Sky 8.430e-15 9.53e-11 9.76e-06
        Dark Current 0.001 11.87 3.44
Total in selected region 0.013 146.13 13.43
Brightest Pixel (single exposure) (at 1215.40 Å) 12.545 70,884.29
Count rate entire detector 3,684.750

Buffer Time (sec) 542.78
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 2,124.897 12,006,722.113
    Background (sky+dark) 157.420 889,501.72

Encircled energy fraction 0.93


Instrument name: STIS
Mode: spectroscopic
Detector: FUVMAMA
Central Wavelength: 1425
Grating: [E140M] R ~ 45800
Aperture: 0.2X0.2
Glow region: low


Target: [point source]
Spectrum: User uploaded spectrum: flare_moderate.dat
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.1.1