ETC Request ID: STIS.sp.826456

Requested Signal/Noise Ratio = 10.000 at wavelength 1718.00 Å (per resolution element)

gives: Time = 574.8144 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x pix) (2.0 pix resel x pix)
    Source 0.109 125.53 11.20
    Background 0.011 12.07 3.47
        Sky 2.641e-11 3.04e-08 1.74e-04
        Dark Current 0.011 12.07 3.47
Total in selected region 0.120 137.61 12.55
Brightest Pixel (single exposure) (at 2345.53 Å) 0.152 87.09
Count rate entire detector 6,765.310

Buffer Time (sec) 295.63
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 4,088.541 2,350,152.505
    Background (sky+dark) 1,572.864 904,104.97

Encircled energy fraction 0.92


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength: 1978
Grating: [E230M] R ~ 30000
Aperture: 0.2X0.2


Target: [point source]
Spectrum: Castelli-Kurucz Models O7V 37000 4.0
Extinction E(B-V): Milky Way Diffuse (Rv=3.1) = 0.56 applied before normalization
Normalization: Renormalized to vegamag = 10.09 in filter Johnson/V
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 24.2