ETC Request ID: STIS.sp.821475

Requested Signal/Noise Ratio = 100.000 at wavelength 2732.00 Å (per resolution element)

gives: Time = 12,578.4527 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x pix) (2.0 pix resel x pix)
    Source 0.408 10,257.58 101.28
    Background 0.011 264.21 16.25
        Sky 2.498e-06 0.06 0.25
        Dark Current 0.011 264.15 16.25
Total in selected region 0.418 10,521.79 102.58
Brightest Pixel (single exposure) (at 2884.80 Å) 0.370 4,660.24
Count rate entire detector 1,947.963

Buffer Time (sec) 1,026.71
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 373.370 4,696,417.960
    Background (sky+dark) 1,574.593 19,805,945.65

Encircled energy fraction 0.86


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength:
Grating: [G230L] R ~ 500
Aperture: 52X0.2


Target: [point source]
Spectrum: User uploaded spectrum: Mrk493_forETC_daeseong.dat
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 24.2