ETC Request ID: STIS.sp.820956

Exposure time (seconds) = 2,453.0000 at wavelength 1300.00 Å

gives: SNR = 66.3740 (per resolution element)

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: Buffer time 52.5181 is less than minimum 99 seconds.


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x pix) (2.0 pix resel x pix)
    Source 1.127 5,529.53 74.36
    Background 0.001 5.15 2.27
        Sky 8.434e-15 4.14e-11 6.43e-06
        Dark Current 0.001 5.15 2.27
Total in selected region 1.128 5,534.69 83.31
Brightest Pixel (single exposure) (at 1297.42 Å) 0.395 969.08
Count rate entire detector 38,082.115

Buffer Time (sec) 52.52
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 22,846.195 56,041,716.214
    Background (sky+dark) 157.420 386,152.00

Encircled energy fraction 0.93


Instrument name: STIS
Mode: spectroscopic
Detector: FUVMAMA
Central Wavelength: 1425
Grating: [E140M] R ~ 45800
Aperture: 0.2X0.2
Glow region: low


Target: [point source]
Spectrum: Black body at 47250.0K
Extinction E(B-V): None
Normalization: Flux 7.5e-12 flam at 1300.0 Å
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 24.2