ETC Request ID: STIS.sp.820552

Requested Signal/Noise Ratio = 15.000 at wavelength 1808.00 Å (per resolution element)

gives: Time = 1,134.0510 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x pix) (2.0 pix resel x pix)
    Source 0.122 275.58 16.60
    Background 0.011 23.82 4.88
        Sky 8.882e-11 2.01e-07 4.49e-04
        Dark Current 0.011 23.82 4.88
Total in selected region 0.132 299.40 18.37
Brightest Pixel (single exposure) (at 2267.06 Å) 0.255 289.22
Count rate entire detector 7,596.998

Buffer Time (sec) 263.26
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 4,743.413 5,379,272.400
    Background (sky+dark) 1,572.864 1,783,708.01

Encircled energy fraction 0.92


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength: 1978
Grating: [E230M] R ~ 30000
Aperture: 0.2X0.2


Target: [point source]
Spectrum: User uploaded spectrum: sk-6635IUE_coadded.dat
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 24.2