ETC Request ID: STIS.sp.1435608

Exposure time (seconds) = 1,200.0000 at wavelength 1800.00 Å

gives: SNR = 17.4610 (per resolution element)


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.157 377.49 19.43
    Background 0.015 36.96 6.08
        Sky 9.302e-11 2.23e-07 4.72e-04
        Dark Current 0.015 36.96 6.08
Total in selected region 0.173 414.45 21.62
Brightest Pixel (single exposure) (at 2293.00 Å) 0.224 268.60
Count rate entire detector 9,938.089

Buffer Time (sec) 201.25
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 6,008.839 7,210,606.989
    Background (sky+dark) 2,306.867 2,768,240.69

Encircled energy fraction 0.92


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength: 1978
Grating: [E230M] R ~ 30000
Aperture: 0.2X0.2


Target: [point source]
Spectrum: User uploaded spectrum: AV488_newsed.fits
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 28.1