ETC Request ID: STIS.sp.1431331

Requested Signal/Noise Ratio = 10.000 at wavelength 2376.00 Å (per resolution element)

gives: Time = 4.4447 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 11 pixels high) (1 pix x 11 pix) (2 pix resel x 11 pix)
    Source 11.274 100.21 10.01
    Background 0.024 0.22 0.46
        Sky 9.386e-07 8.34e-06 2.89e-03
        Dark Current 0.024 0.22 0.46
Total in selected region 11.298 100.43 10.02
Brightest Pixel (single exposure) (at 2587.20 Å) 4.670 20.75
Count rate entire detector 11,436.427

Buffer Time (sec) 174.88
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 9,127.835 40,570.214
    Background (sky+dark) 2,308.591 10,260.93

Encircled energy fraction 0.79


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength:
Grating: [G230L] R ~ 500
Aperture: 52X0.2


Target: [point source]
Spectrum: Black body at 15000.0K
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 13.1 in filter Johnson/V
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 28.1