ETC Request ID: STIS.sp.1368399

Requested Signal/Noise Ratio = 20.000 at wavelength 2852.00 Å (per resolution element)

gives: Time = 863.1928 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.250 431.63 20.78
    Background 0.014 24.17 4.92
        Sky 1.084e-09 1.87e-06 1.37e-03
        Dark Current 0.014 24.17 4.92
Total in selected region 0.264 455.80 21.58
Brightest Pixel (single exposure) (at 2826.11 Å) 0.131 113.28
Count rate entire detector 8,575.422

Buffer Time (sec) 233.22
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 5,970.754 5,153,911.861
    Background (sky+dark) 2,097.152 1,810,246.56

Encircled energy fraction 0.93


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength: 2912
Grating: [E230H] R ~ 114000
Aperture: 0.2X0.09


Target: [point source]
Spectrum: Castelli-Kurucz Models A5V 8250 4.0
Extinction E(B-V): Milky Way Diffuse (Rv=3.1) = 0.042 applied before normalization
Normalization: Renormalized to vegamag = 8.18 in filter Johnson/U
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 27.2