ETC Request ID: STIS.sp.1365451

Exposure time (seconds) = 900.0000 at wavelength 1450.00 Å

gives: SNR = 19.1101 (per resolution element)

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: Partial overlap between instrument throughput band and target spectrum. Please doublecheck the wavelength range covered by the selected spectrum, and the instrument documentation for the selected filter.


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.234 421.32 20.53
    Background 0.001 1.89 1.37
        Sky 2.902e-14 5.22e-11 7.23e-06
        Dark Current 0.001 1.89 1.37
Total in selected region 0.235 423.21 22.05
Brightest Pixel (single exposure) (at 1356.78 Å) 0.083 74.78
Count rate entire detector 6,699.603

Buffer Time (sec) 298.53
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 3,941.052 3,546,946.950
    Background (sky+dark) 157.418 141,676.35

Encircled energy fraction 0.94


Instrument name: STIS
Mode: spectroscopic
Detector: FUVMAMA
Central Wavelength: 1425
Grating: [E140M] R ~ 45800
Aperture: 0.2X0.2
Glow region: low


Target: [point source]
Spectrum: User uploaded spectrum: hd14476_swp.dat
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 27.2