ETC Request ID: STIS.sp.1353262

Exposure time (seconds) = 2,600.0000 at wavelength 1160.00 Å

gives: SNR = 2.1537 (per resolution element)


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.002 11.11 3.33
    Background 0.001 5.46 2.34
        Sky 7.164e-14 3.73e-10 1.93e-05
        Dark Current 0.001 5.46 2.34
Total in selected region 0.003 16.57 5.16
Brightest Pixel (single exposure) (at 1320.44 Å) 0.015 39.27
Count rate entire detector 1,571.332

Buffer Time (sec) 1,272.81
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 851.755 2,214,562.446
    Background (sky+dark) 157.418 409,287.23

Encircled energy fraction 0.77


Instrument name: STIS
Mode: spectroscopic
Detector: FUVMAMA
Central Wavelength: 1425
Grating: [E140M] R ~ 45800
Aperture: 0.2X0.2
Glow region: low


Target: [point source]
Spectrum: Kurucz Models O7V 38000 4.5
Extinction E(B-V): SMC Bar (Rv=2.74) = 0.08 applied before normalization
Normalization: Renormalized to vegamag = 13.01 in filter Johnson/U
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Earth Shine: Average
    Zodiacal Light: Average
    Air Glow: Average

Table of Source and Noise Counts per Pixel


Plots