ETC Request ID: STIS.sp.1152514

Requested Signal/Noise Ratio = 10.000 at wavelength 2800.00 Å (per resolution element)

gives: Time = 686.0340 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.082 112.80 10.62
    Background 0.011 14.44 3.80
        Sky 2.270e-05 0.03 0.18
        Dark Current 0.011 14.41 3.80
Total in selected region 0.093 127.24 11.28
Brightest Pixel (single exposure) (at 2795.20 Å) 0.227 156.00
Count rate entire detector 1,617.204

Buffer Time (sec) 1,236.70
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 26.935 18,478.273
    Background (sky+dark) 1,590.269 1,090,978.57

Encircled energy fraction 0.87


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength:
Grating: [G230L] R ~ 500
Aperture: 52X2


Target: [point source]
Spectrum: User uploaded spectrum: muscles_M1.5.csv
Extinction E(B-V): None
Normalization: Renormalized to abmag = 20.99 in filter Galex/NUV
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2