ETC Request ID: STIS.sp.1038652

Exposure time (seconds) = 1.0000 at wavelength 3000.00 Å

gives: SNR = 84.7061 (per resolution element)

gives: Time to Saturation (for a single exposure) = 3.02 seconds

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: "Electrons per pixel due to background (0.009) is less than the recommended threshold of 20 electrons to avoid poor charge transfer efficiency (CTE). We suggest you consider CTE mitigation strategies described in the STIS Instrument Handbook."


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(e-/s) (e-) (e-)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 4,062.873 8,125.75 90.14
    Background 0.126 0.25 0.50
        Sky 2.778e-06 5.56e-06 2.36e-03
        Dark Current 0.126 0.25 0.50
    Read Out 32.81
Total in selected region 4,062.999 8,126.00 95.93
Brightest Pixel (single exposure) (at 4571.30 Å) 10,931.906 5,465.95

Global Count Rates
    Source only 22,077,511.453 22,077,511.453
    Background (sky+dark) 18,874.463 18,874.46

Encircled energy fraction 0.94


Instrument name: STIS
Mode: spectroscopic
Detector: CCD
Central Wavelength:
Grating: [G430L] R ~ 500
Aperture: 0.2X0.06
Gain: 1.0
# Frames: 2
Binning: dispersion: 1, spatial: 1
Dark: medium


Target: [point source]
Spectrum: Kurucz Models O9V 33000. 4.0
Extinction E(B-V): Milky Way Diffuse (Rv=3.1) = 0.62 applied before normalization
Normalization: Renormalized to vegamag = 5.95 in filter Johnson/V
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2