ETC Request ID: STIS.sp.1018449

Exposure time (seconds) = 2,000.0000 at wavelength 2376.00 Å

gives: SNR = 12.3676 (per resolution element)


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.047 187.26 13.68
    Background 0.011 42.00 6.48
        Sky 6.074e-07 2.43e-03 0.05
        Dark Current 0.011 42.00 6.48
Total in selected region 0.057 229.27 15.14
Brightest Pixel (single exposure) (at 2699.20 Å) 0.025 50.99
Count rate entire detector 1,614.188

Buffer Time (sec) 1,239.01
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 39.581 79,162.803
    Background (sky+dark) 1,574.606 3,149,212.85

Encircled energy fraction 0.85


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength:
Grating: [G230L] R ~ 500
Aperture: 52X0.2


Target: [point source]
Spectrum: Power Law with index 1.0
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 17.0 in filter Johnson/U
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2