ETC Request ID: STIS.sp.1013546

Exposure time (seconds) = 2,192.0000 at wavelength 1216.00 Å

gives: SNR = 5.9837 (per resolution element)


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.012 54.41 7.38
    Background 0.001 4.60 2.15
        Sky 1.399e-14 6.14e-11 7.83e-06
        Dark Current 0.001 4.60 2.15
Total in selected region 0.013 59.02 9.09
Brightest Pixel (single exposure) (at 1215.08 Å) 0.121 265.86
Count rate entire detector 193.505

Buffer Time (sec) 10,335.67
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 19.809 43,422.174
    Background (sky+dark) 160.621 352,081.14

Encircled energy fraction 0.88


Instrument name: STIS
Mode: spectroscopic
Detector: FUVMAMA
Central Wavelength: 1425
Grating: [E140M] R ~ 45800
Aperture: 52X0.05
Glow region: low


Target: [point source]
Spectrum: User uploaded spectrum: GJ783A_lyman_alpha_spectrum.txt
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2