ETC Request ID: STIS.sp.1011368

Requested Signal/Noise Ratio = 10.000 at wavelength 1215.97 Å (per resolution element)

gives: Time = 634.1809 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.123 156.03 12.49
    Background 0.069 87.41 9.35
        Sky 0.068 86.08 9.28
        Dark Current 0.001 1.33 1.15
Total in selected region 0.192 243.44 15.60
Brightest Pixel (single exposure) (at 1215.90 Å) 0.051 32.05
Count rate entire detector 214.233

Buffer Time (sec) 9,335.65
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 0.370 234.826
    Background (sky+dark) 213.862 135,627.43

Encircled energy fraction 0.76


Instrument name: STIS
Mode: spectroscopic
Detector: FUVMAMA
Central Wavelength:
Grating: [G140L] R ~ 1000
Aperture: 52X0.1
Glow region: low


Target: [point source]
Spectrum: Empty
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines:
Line at Center 1215.97 Å    FWHM 0.12 Å   Flux 1.12e-14 Fλ


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2