ETC Request ID: STIS.sp.1011357

Requested Signal/Noise Ratio = 40.000 at wavelength 2850.00 Å (per resolution element)

gives: Time = 297.3585 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 2.701 1,606.22 40.08
    Background 0.011 6.25 2.50
        Sky 1.875e-06 1.12e-03 0.03
        Dark Current 0.011 6.24 2.50
Total in selected region 2.711 1,612.47 40.16
Brightest Pixel (single exposure) (at 2956.80 Å) 1.156 343.79
Count rate entire detector 2,725.073

Buffer Time (sec) 733.93
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 1,150.466 342,101.038
    Background (sky+dark) 1,574.606 468,222.67

Encircled energy fraction 0.87


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength:
Grating: [G230L] R ~ 500
Aperture: 52X0.2


Target: [point source]
Spectrum: Black body at 3850.0K
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 9.585 in filter Johnson/V
Redshift: None
Emission Lines:
Line at Center 2796.1 Å    FWHM 1.73 Å   Flux 1.3e-14 Fλ
Line at Center 2804.0 Å    FWHM 1.73 Å   Flux 9.7e-15 Fλ


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2