ETC Request ID: STIS.sp.1008229

Exposure time (seconds) = 1,070.0000 at wavelength 1450.00 Å

gives: SNR = 7.8521 (per resolution element)


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.030 63.83 7.99
    Background 0.001 2.25 1.50
        Sky 2.652e-12 5.68e-09 7.53e-05
        Dark Current 0.001 2.25 1.50
Total in selected region 0.031 66.07 8.13
Brightest Pixel (single exposure) (at 1215.30 Å) 0.353 377.81
Count rate entire detector 372.183

Buffer Time (sec) 5,373.70
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 101.745 108,866.705
    Background (sky+dark) 270.438 289,369.01

Encircled energy fraction 0.83


Instrument name: STIS
Mode: spectroscopic
Detector: FUVMAMA
Central Wavelength:
Grating: [G140L] R ~ 1000
Aperture: 52X0.2
Glow region: low


Target: [point source]
Spectrum: User uploaded spectrum: m81fos.txt
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2