ETC Request ID: STIS.sp.1007559

Requested Signal/Noise Ratio = 5.000 at wavelength 2850.00 Å (per resolution element)

gives: Time = 4,690.1795 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.007 63.68 7.98
    Background 0.011 98.51 9.93
        Sky 1.875e-06 0.02 0.13
        Dark Current 0.011 98.49 9.92
Total in selected region 0.017 162.19 12.74
Brightest Pixel (single exposure) (at 2798.40 Å) 0.058 273.83
Count rate entire detector 1,581.719

Buffer Time (sec) 1,264.45
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 7.113 33,359.780
    Background (sky+dark) 1,574.606 7,385,186.72

Encircled energy fraction 0.87


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength:
Grating: [G230L] R ~ 500
Aperture: 52X0.2


Target: [point source]
Spectrum: User uploaded spectrum: gj1132.dat
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2