ETC Request ID: STIS.sp.1005924

Exposure time (seconds) = 2,000.0000 at wavelength 2800.00 Å

gives: SNR = 8.4364 (per resolution element)


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.025 101.96 10.10
    Background 0.011 42.00 6.48
        Sky 1.442e-08 5.77e-05 7.60e-03
        Dark Current 0.011 42.00 6.48
Total in selected region 0.036 143.96 12.09
Brightest Pixel (single exposure) (at 2911.51 Å) 0.095 189.28
Count rate entire detector 3,651.866

Buffer Time (sec) 547.67
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 1,690.242 3,380,484.426
    Background (sky+dark) 1,572.868 3,145,735.18

Encircled energy fraction 0.93


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength: 2707
Grating: [E230M] R ~ 30000
Aperture: 0.2X0.2


Target: [point source]
Spectrum: Castelli-Kurucz Models F8V 6250 4.0
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 10.05 in filter Johnson/V
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2