ETC Request ID: STIS.sp.916561

Exposure time (seconds) = 4,850.0000 at wavelength 2260.00 Å

gives: SNR = 37.3957 (per resolution element)


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x pix) (2.0 pix resel x pix)
    Source 0.163 1,581.71 39.77
    Background 0.011 101.85 10.09
        Sky 4.578e-10 4.44e-06 2.11e-03
        Dark Current 0.011 101.85 10.09
Total in selected region 0.174 1,683.56 42.30
Brightest Pixel (single exposure) (at 2375.25 Å) 0.087 423.07
Count rate entire detector 8,721.194

Buffer Time (sec) 229.33
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 5,263.863 25,529,734.928
    Background (sky+dark) 1,572.864 7,628,390.46

Encircled energy fraction 0.93


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength: 2263
Grating: [E230H] R ~ 114000
Aperture: 0.2X0.09


Target: [point source]
Spectrum: Flat in units of Fλ
Extinction E(B-V): None
Normalization: Flux 1.3e-12 flam at 2260.0 Å
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.1.1