ETC Request ID: STIS.ta.825915

Requested Signal/Noise Ratio = 40.000

gives: Time = 0.0021 seconds

gives: Time to Saturation (for a single exposure) = 0.85 seconds

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: Result of the calculation 0.00210201 is less than the minimum exposure time for this detector (0.1)

WARNING MESSAGE: Partial overlap between instrument throughput band and target spectrum. Please doublecheck the wavelength range covered by the selected spectrum, and the instrument documentation for the selected filter.



Plots


Detailed Information Count rate Total counts Associated noise
(e-/s) (e-) (e-)
Counts (box of 3 x 3 pixels)
    Source 997,285.273 2,096.30 45.79
    Background 0.608 1.28e-03 0.04
        Sky 0.437 9.18e-04 0.03
        Dark Current 0.171 3.59e-04 0.02
    Read Out 25.50
Total in selected region 997,285.881 2,096.30 52.41
Brightest Pixel (single exposure) 141,087.073 296.57

Global Count Rates
    Source only 997,285.273 2,096.303
    Background (sky+dark) 47,758.524 100.39

Background per unit area
    Sky Background (arcsec-2) 19.417 0.041
    Dark Current (arcsec-2) 7.600 0.016

Extraction region
box of 3 x 3 pixels
    Effective Sky Area (pixels) 9.00
Effective Wavelength 7163.38 Å


Instrument name: STIS
Mode: Target Acquisition
Detector: CCD
Acquisition Mode: ACQ
Aperture: F28X50LP
Gain: 4.0
# Frames: 1
Binning: 1
Dark:


Target: [extended source]
Source diameter (arcsec): 0.15
Spectrum: Standard HST Star Spectra Solar Spectrum (G2V, -26.75) [1195.0, 26957.4 Å]
Extinction E(B-V): None
Normalization: Renormalized to abmag = 5.9 in filter Sloan/R
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:


Plots

These results were computed using: ETC version 24.2