ETC Request ID: STIS.sp.825205

Exposure time (seconds) = 2,800.0000 at wavelength 1600.00 Å

gives: SNR = 9.9503 (per resolution element)


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x pix) (2.0 pix resel x pix)
    Source 0.020 114.40 10.70
    Background 0.001 5.88 2.42
        Sky 3.429e-13 1.92e-09 4.38e-05
        Dark Current 0.001 5.88 2.42
Total in selected region 0.021 120.28 11.50
Brightest Pixel (single exposure) (at 1320.92 Å) 0.042 117.96
Count rate entire detector 4,149.949

Buffer Time (sec) 481.93
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 2,405.137 6,734,382.388
    Background (sky+dark) 157.420 440,776.85

Encircled energy fraction 0.95


Instrument name: STIS
Mode: spectroscopic
Detector: FUVMAMA
Central Wavelength: 1425
Grating: [E140M] R ~ 45800
Aperture: 0.2X0.2
Glow region: low


Target: [point source]
Spectrum: Castelli-Kurucz Models O7V 37000 4.0
Extinction E(B-V): LMC Diffuse (Rv=3.41) = 0.12 applied before normalization
Normalization: Renormalized to vegamag = 13.24 in filter Johnson/V
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 24.2