ETC Request ID: STIS.ta.823508

Requested Signal/Noise Ratio = 40.000

gives: Time = 0.0777 seconds

gives: Time to Saturation (for a single exposure) = 11.29 seconds

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: Result of the calculation 0.0777433 is less than the minimum exposure time for this detector (0.1)



Plots


Detailed Information Count rate Total counts Associated noise
(e-/s) (e-) (e-)
Counts (box of 3 x 3 pixels)
    Source 26,964.798 2,096.33 45.79
    Background 0.608 0.05 0.22
        Sky 0.437 0.03 0.18
        Dark Current 0.171 0.01 0.12
    Read Out 25.50
Total in selected region 26,965.406 2,096.38 52.41
Brightest Pixel (single exposure) 10,629.780 826.39

Global Count Rates
    Source only 53,929.596 4,192.663
    Background (sky+dark) 47,758.524 3,712.90

Background per unit area
    Sky Background (arcsec-2) 19.417 1.510
    Dark Current (arcsec-2) 7.600 0.591

Extraction region
box of 3 x 3 pixels
    Effective Sky Area (pixels) 9.00
    Fraction of flux 0.50
    Fraction of flux in brightest pixel 0.20
Effective Wavelength 6969.35 Å


Instrument name: STIS
Mode: Target Acquisition
Detector: CCD
Acquisition Mode: ACQ
Aperture: F28X50LP
Gain: 4.0
# Frames: 1
Binning: 1
Dark:


Target: [point source]
Spectrum: Black body at 10000.0K
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 13.26 in filter Johnson/V
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:


Plots

These results were computed using: ETC version 24.2