ETC Request ID: STIS.ta.822658

Requested Signal/Noise Ratio = 40.000

gives: Time = 0.0367 seconds

gives: Time to Saturation (for a single exposure) = 1.86 seconds

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: Result of the calculation 0.0367497 is less than the minimum exposure time for this detector (0.1)

WARNING MESSAGE: Partial overlap between instrument throughput band and target spectrum. Please doublecheck the wavelength range covered by the selected spectrum, and the instrument documentation for the selected filter.



Plots


Detailed Information Count rate Total counts Associated noise
(e-/s) (e-) (e-)
Counts (box of 32 x 32 pixels)
    Source 318,626.372 11,709.44 108.21
    Background 24.789 0.91 0.95
        Sky 5.333 0.20 0.44
        Dark Current 19.456 0.72 0.85
    Read Out 272.00
Total in selected region 318,651.161 11,710.35 292.74
Brightest Pixel (single exposure) 64,403.023 2,366.79

Global Count Rates
    Source only 348,054.117 12,790.901
    Background (sky+dark) 20,093.594 738.43

Background per unit area
    Sky Background (arcsec-2) 33.330 1.225
    Dark Current (arcsec-2) 7.600 0.279

Extraction region
box of 32 x 32 pixels
    Effective Sky Area (pixels) 64.00
    Fraction of flux 0.92
    Fraction of flux in brightest pixel 0.19
Effective Wavelength 7304.53 Å


Instrument name: STIS
Mode: Target Acquisition
Detector: CCD
Acquisition Mode: ACQ/PEAK
Aperture: 52X0.1
Gain: 4.0
# Frames: 1
Binning: 1
Dark:


Target: [point source]
Spectrum: User uploaded spectrum: dim.dat
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:


Plots

These results were computed using: ETC version 24.2