ETC Request ID: STIS.sp.822431

Requested Signal/Noise Ratio = 60.000 at wavelength 2000.00 Å (per resolution element)

gives: Time = 56,608.3731 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x pix) (2.0 pix resel x pix)
    Source 0.042 4,804.04 69.31
    Background 0.011 1,188.78 34.48
        Sky 4.269e-11 4.83e-06 2.20e-03
        Dark Current 0.011 1,188.78 34.48
Total in selected region 0.053 5,992.82 80.07
Brightest Pixel (single exposure) (at 2080.35 Å) 0.040 2,258.91
Count rate entire detector 3,495.124

Buffer Time (sec) 572.23
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 1,295.327 73,326,356.184
    Background (sky+dark) 1,572.864 89,037,272.19

Encircled energy fraction 0.93


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength: 1963
Grating: [E230H] R ~ 114000
Aperture: 0.2X0.09


Target: [point source]
Spectrum: Castelli-Kurucz Models F2V 7000 4.0
Extinction E(B-V): None
Normalization: Flux 6.6e-13 flam at 2000.0 Å
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 24.2