ETC Request ID: STIS.sp.794658
Requested Signal/Noise Ratio = 55.000 at wavelength 2000.00 Å (per resolution element)
gives: Time = 58,730.3094 seconds
Table of Source and Noise Counts per Pixel
| Detailed Information | Count rate | Total counts | Associated noise |
| (counts/s) | (counts) | (counts) | |
| Counts (box 7 pixels high) | (1 pix x pix) | (2.0 pix resel x pix) | |
| Source | 0.036 | 4,180.60 | 64.66 |
| Background | 0.011 | 1,233.34 | 35.12 |
| Sky | 4.727e-11 | 5.55e-06 | 2.36e-03 |
| Dark Current | 0.011 | 1,233.34 | 35.12 |
| Total in selected region | 0.046 | 5,413.94 | 76.01 |
| Brightest Pixel (single exposure) (at 2115.00 Å) | 0.038 | 2,232.22 | |
| Count rate entire detector | 3,732.344 | ||
| Buffer Time (sec) | 535.86 | ||
| For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details. | |||
|
|
|||
| Global Count Rates | |||
| Source only | 1,476.068 | 86,689,913.089 | |
| Background (sky+dark) | 1,572.864 | 92,374,789.48 | |
| Encircled energy fraction | 0.93 | ||
| Instrument name: | STIS |
| Mode: | spectroscopic |
| Detector: | NUVMAMA |
| Central Wavelength: | 2013 |
| Grating: | [E230H] R ~ 114000 |
| Aperture: | 0.2X0.09 |
| Target: [point source] | |
| Spectrum: | Castelli-Kurucz Models F2V 7000 4.0 |
| Extinction E(B-V): | None |
| Normalization: | Flux 5e-13 flam at 2000.0 Å |
| Redshift: | None |
| Emission Lines: | None |
| Selected background: | |
| Sky Background: | |
| Level: |
Table of Source and Noise Counts per Pixel
These results were computed using: ETC version 24.1