ETC Request ID: STIS.im.757956

Exposure time (seconds) = 5.0000

gives: SNR = 50.2640

gives: Time to Saturation (for a single exposure) = 509.39 seconds

gives: Optimum SNR = 71.9120

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: "Electrons per pixel due to background (0.095) is less than the recommended threshold of 20 electrons to avoid poor charge transfer efficiency (CTE). We suggest you consider CTE mitigation strategies described in the STIS Instrument Handbook."



Plots


Detailed Information Count rate Total counts Associated noise
(e-/s) (e-) (e-)
Counts (circle with radius 0.258 arcsec)
    Source 1,076.038 5,380.19 73.35
    Background 1.611 8.05 2.84
        Sky 0.015 0.07 0.27
        Dark Current 1.596 7.98 2.82
    Read Out 77.90
Total in selected region 1,077.648 5,388.24 107.04
Brightest Pixel (single exposure) 235.574 1,177.87

Global Count Rates
    Source only 1,345.047 6,725.236
    Background (sky+dark) 19,966.577 99,832.88

Background per unit area
    Sky Background (arcsec-2) 0.070 0.349
    Dark Current (arcsec-2) 7.600 38.000

Extraction region
circle with radius 0.258 arcsec
    Effective Sky Area (pixels) 83.73
    Fraction of flux 0.80
    Fraction of flux in brightest pixel 0.18
Effective Wavelength 7577.63 Å


Instrument name: STIS
Mode: imaging
Detector: CCD
Aperture: F25ND3
Gain: 4.0
# Frames: 1
Binning: 1
Dark:


Target: [point source]
Spectrum: Pickles Models M0V 3801.89K
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 12.167 in filter Johnson/V
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:


Plots

These results were computed using: ETC version 24.1