ETC Request ID: STIS.ta.1368232
Requested Signal/Noise Ratio = 100.000
gives: Time = 3.6183 seconds
gives: Time to Saturation (for a single exposure) = 101.66 seconds
| Detailed Information | Count rate | Total counts | Associated noise |
| (e-/s) | (e-) | (e-) | |
| Counts (box of 3 x 3 pixels) | |||
| Source | 2,929.943 | 10,601.30 | 102.96 |
| Background | 0.666 | 2.41 | 1.55 |
| Sky | 0.432 | 1.56 | 1.25 |
| Dark Current | 0.234 | 0.85 | 0.92 |
| Read Out | 25.20 | ||
| Total in selected region | 2,930.609 | 10,603.71 | 106.01 |
| Brightest Pixel (single exposure) | 1,180.405 | 4,271.01 | |
|
|
|||
| Global Count Rates | |||
| Source only | 5,859.885 | 21,202.592 | |
| Background (sky+dark) | 54,817.750 | 198,344.90 | |
|
|
|||
| Background per unit area | |||
| Sky Background (arcsec-2) | 19.221 | 69.545 | |
| Dark Current (arcsec-2) | 10.400 | 37.630 | |
| Extraction region | |||
| box of 3 x 3 pixels | |||
| Effective Sky Area (pixels) | 9.00 | ||
| Fraction of flux | 0.50 | ||
| Fraction of flux in brightest pixel | 0.20 | ||
| Effective Wavelength | 6849.29 Å | ||
| Instrument name: | STIS |
| Mode: | Target Acquisition |
| Detector: | CCD |
| Acquisition Mode: | ACQ |
| Aperture: | F28X50LP |
| Gain: | 4.0 |
| # Frames: | 1 |
| Binning: | 1 |
| Dark: | medium |
| Target: [point source] | |
| Spectrum: | Castelli-Kurucz Models O5V 41000 4.5 |
| Extinction E(B-V): | LMC Diffuse (Rv=3.41) = 0.15 applied before normalization |
| Normalization: | Renormalized to vegamag = 13.244 in filter WFC3/UVIS1/F275W |
| Redshift: | None |
| Emission Lines: | None |
| Selected background: | |
| Sky Background: | |
| Level: |
These results were computed using: ETC version 27.2