ETC Request ID: STIS.sp.1368221

Exposure time (seconds) = 2,600.0000 at wavelength 1425.00 Å

gives: SNR = 2.5935 (per resolution element)


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.002 11.11 3.33
    Background 0.001 5.46 2.34
        Sky 2.171e-14 1.13e-10 1.06e-05
        Dark Current 0.001 5.46 2.34
Total in selected region 0.003 16.57 4.29
Brightest Pixel (single exposure) (at 1215.70 Å) 0.003 6.58
Count rate entire detector 247.543

Buffer Time (sec) 8,079.39
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 54.292 141,159.967
    Background (sky+dark) 157.418 409,287.23

Encircled energy fraction 0.94


Instrument name: STIS
Mode: spectroscopic
Detector: FUVMAMA
Central Wavelength: 1425
Grating: [E140M] R ~ 45800
Aperture: 0.2X0.2
Glow region: low


Target: [point source]
Spectrum: Castelli-Kurucz Models O9V 33000 4.0
Extinction E(B-V): SMC Bar (Rv=2.74) = 0.5 applied before normalization
Normalization: Renormalized to vegamag = 11.853 in filter Johnson/U
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 27.2