ETC Request ID: STIS.sp.1354183
Exposure time (seconds) = 2,600.0000 at wavelength 1425.00 Å
gives: SNR = 8.7611 (per resolution element)
Table of Source and Noise Counts per Pixel
| Detailed Information | Count rate | Total counts | Associated noise |
| (counts/s) | (counts) | (counts) | |
| Counts (box 7 pixels high) | (1 pix x 7 pix) | (2 pix resel x 7 pix) | |
| Source | 0.018 | 93.59 | 9.67 |
| Background | 0.001 | 5.46 | 2.34 |
| Sky | 2.171e-14 | 1.13e-10 | 1.06e-05 |
| Dark Current | 0.001 | 5.46 | 2.34 |
| Total in selected region | 0.019 | 99.05 | 10.68 |
| Brightest Pixel (single exposure) (at 1344.93 Å) | 0.008 | 19.69 | |
| Count rate entire detector | 906.908 | ||
| Buffer Time (sec) | 2,205.30 | ||
| For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details. | |||
|
|
|||
| Global Count Rates | |||
| Source only | 451.499 | 1,173,898.595 | |
| Background (sky+dark) | 157.418 | 409,287.23 | |
| Encircled energy fraction | 0.94 | ||
| Instrument name: | STIS |
| Mode: | spectroscopic |
| Detector: | FUVMAMA |
| Central Wavelength: | 1425 |
| Grating: | [E140M] R ~ 45800 |
| Aperture: | 0.2X0.2 |
| Glow region: | low |
| Target: [point source] | |
| Spectrum: | Castelli-Kurucz Models O5V 41000 4.5 |
| Extinction E(B-V): | LMC Diffuse (Rv=3.41) = 0.29 applied before normalization |
| Normalization: | Renormalized to vegamag = 12.347 in filter WFC3/UVIS1/F275W |
| Redshift: | None |
| Emission Lines: | None |
| Selected background: | |
| Sky Background: | |
| Level: |
Table of Source and Noise Counts per Pixel
These results were computed using: ETC version 27.1