ETC Request ID: STIS.sp.1314361

Exposure time (seconds) = 300.0000 at wavelength 6252.00 Å

gives: SNR = 16.0823 (per resolution element)

gives: Time to Saturation (for a single exposure) = 32,326.04 seconds

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: "Electrons per pixel due to background (2.6) is less than the recommended threshold of 20 electrons to avoid poor charge transfer efficiency (CTE). We suggest you consider CTE mitigation strategies described in the STIS Instrument Handbook."


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(e-/s) (e-) (e-)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 1.717 1,030.19 32.10
    Background 0.183 109.60 10.47
        Sky 6.704e-04 0.40 0.63
        Dark Current 0.182 109.20 10.45
    Read Out 54.44
Total in selected region 1.900 1,139.79 64.06
Brightest Pixel (single exposure) (at 6311.95 Å) 3.712 371.22

Global Count Rates
    Source only 2,065.005 619,501.516
    Background (sky+dark) 27,366.929 8,210,078.59

Encircled energy fraction 0.92


Instrument name: STIS
Mode: spectroscopic
Detector: CCD
Central Wavelength: 6252
Grating: [G750M] R ~ 5000
Aperture: 52X0.5
Gain: 4.0
# Frames: 3
Binning: dispersion: 1, spatial: 1
Dark: medium


Target: [point source]
Spectrum: Non-stellar Objects Planetary Nebula and Pt Source
Extinction E(B-V): None
Normalization: Flux 2.02e-15 flam at 6510.0 Å
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 27.1