ETC Request ID: STIS.ta.1297953
Requested Signal/Noise Ratio = 40.000
gives: Time = 9.9468 seconds
gives: Time to Saturation (for a single exposure) = 5,121.60 seconds
Exposure time calculation HAD WARNINGS.
WARNING MESSAGE: Partial overlap between instrument throughput band and target spectrum. Please doublecheck the wavelength range covered by the selected spectrum, and the instrument documentation for the selected filter.
| Detailed Information | Count rate | Total counts | Associated noise |
| (e-/s) | (e-) | (e-) | |
| Counts (box of 3 x 3 pixels) | |||
| Source | 210.212 | 2,090.95 | 45.73 |
| Background | 0.659 | 6.56 | 2.56 |
| Sky | 0.434 | 4.32 | 2.08 |
| Dark Current | 0.225 | 2.24 | 1.50 |
| Read Out | 25.20 | ||
| Total in selected region | 210.872 | 2,097.51 | 52.27 |
| Brightest Pixel (single exposure) | 23.430 | 233.06 | |
|
|
|||
| Global Count Rates | |||
| Source only | 13,393,803.781 | 133,226,109.409 | |
| Background (sky+dark) | 53,877.858 | 535,914.77 | |
|
|
|||
| Background per unit area | |||
| Sky Background (arcsec-2) | 19.296 | 191.939 | |
| Dark Current (arcsec-2) | 10.000 | 99.468 | |
| Extraction region | |||
| box of 3 x 3 pixels | |||
| Effective Sky Area (pixels) | 9.00 | ||
| Effective Wavelength | 7171.81 Å | ||
| Instrument name: | STIS |
| Mode: | Target Acquisition |
| Detector: | CCD |
| Acquisition Mode: | ACQ |
| Aperture: | F28X50LP |
| Gain: | 4.0 |
| # Frames: | 1 |
| Binning: | 1 |
| Dark: | medium |
| Target: [extended source] | |
| Source diameter (arcsec): | 9000.0 |
| Spectrum: | Standard HST Star Spectra Solar Spectrum (G2V, -26.75) [1195.0, 26957.4 Å] |
| Extinction E(B-V): | None |
| Normalization: | Renormalized to vegamag = 15.5 in filter Johnson/V |
| Redshift: | None |
| Emission Lines: | None |
| Selected background: | |
| Sky Background: | |
| Level: |
These results were computed using: ETC version 26.2