ETC Request ID: STIS.ta.1288949
Requested Signal/Noise Ratio = 40.000
gives: Time = 0.1104 seconds
gives: Time to Saturation (for a single exposure) = 20.99 seconds
| Detailed Information | Count rate | Total counts | Associated noise |
| (e-/s) | (e-) | (e-) | |
| Counts (box of 3 x 3 pixels) | |||
| Source | 18,906.237 | 2,086.93 | 45.68 |
| Background | 0.659 | 0.07 | 0.27 |
| Sky | 0.434 | 0.05 | 0.22 |
| Dark Current | 0.225 | 0.02 | 0.16 |
| Read Out | 25.20 | ||
| Total in selected region | 18,906.896 | 2,087.00 | 52.17 |
| Brightest Pixel (single exposure) | 5,718.286 | 631.20 | |
|
|
|||
| Global Count Rates | |||
| Source only | 37,812.474 | 4,173.853 | |
| Background (sky+dark) | 53,877.858 | 5,947.20 | |
|
|
|||
| Background per unit area | |||
| Sky Background (arcsec-2) | 19.296 | 2.130 | |
| Dark Current (arcsec-2) | 10.000 | 1.104 | |
| Extraction region | |||
| box of 3 x 3 pixels | |||
| Effective Sky Area (pixels) | 9.00 | ||
| Fraction of flux | 0.50 | ||
| Fraction of flux in brightest pixel | 0.15 | ||
| Effective Wavelength | 8223.63 Å | ||
| Instrument name: | STIS |
| Mode: | Target Acquisition |
| Detector: | CCD |
| Acquisition Mode: | ACQ |
| Aperture: | F28X50LP |
| Gain: | 4.0 |
| # Frames: | 1 |
| Binning: | 1 |
| Dark: | medium |
| Target: [point source] | |
| Spectrum: | User uploaded spectrum: muscles_M5.csv |
| Extinction E(B-V): | None |
| Normalization: | Renormalized to vegamag = 15.62 in filter Johnson/V |
| Redshift: | None |
| Emission Lines: | None |
| Selected background: | |
| Sky Background: | |
| Level: |
These results were computed using: ETC version 26.1