ETC Request ID: STIS.sp.1177436
Exposure time (seconds) = 250.0000 at wavelength 1400.00 Å
gives: SNR = 117.0410 (per resolution element)
Exposure time calculation HAD WARNINGS.
WARNING MESSAGE: MAMA Bright limits: total count rate per image 21737.1 exceeds limit for irregularly-variable sources 40 percent of the bright limit 30000 counts per second
WARNING MESSAGE: Buffer time 92.0085 is less than minimum 99 seconds.
Table of Source and Noise Counts per Pixel
| Detailed Information | Count rate | Total counts | Associated noise |
| (counts/s) | (counts) | (counts) | |
| Counts (box 7 pixels high) | (1 pix x 7 pix) | (2 pix resel x 7 pix) | |
| Source | 27.398 | 13,699.13 | 117.04 |
| Background | 0.001 | 0.53 | 0.72 |
| Sky | 2.445e-12 | 1.22e-09 | 3.50e-05 |
| Dark Current | 0.001 | 0.53 | 0.72 |
| Total in selected region | 27.399 | 13,699.65 | 117.05 |
| Brightest Pixel (single exposure) (at 1244.10 Å) | 21.974 | 5,493.52 | |
| Count rate entire detector | 21,737.116 | ||
| Buffer Time (sec) | 92.01 | ||
| For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details. | |||
|
|
|||
| Global Count Rates | |||
| Source only | 21,466.815 | 5,366,703.843 | |
| Background (sky+dark) | 270.300 | 67,575.04 | |
| Encircled energy fraction | 0.82 | ||
| Instrument name: | STIS |
| Mode: | spectroscopic |
| Detector: | FUVMAMA |
| Central Wavelength: | |
| Grating: | [G140L] R ~ 1000 |
| Aperture: | 52X0.2 |
| Glow region: | low |
| Target: [point source] | |
| Spectrum: | User uploaded spectrum: calibrated_uv_w3.dat |
| Extinction E(B-V): | None |
| Normalization: | None |
| Redshift: | None |
| Emission Lines: | None |
| Selected background: | |
| Sky Background: | |
| Level: |
Table of Source and Noise Counts per Pixel
These results were computed using: ETC version 26.1