ETC Request ID: STIS.sp.1166374
Exposure time (seconds) = 2,800.0000 at wavelength 2800.00 Å
gives: SNR = 90.8362 (per resolution element)
Exposure time calculation HAD WARNINGS.
WARNING MESSAGE: MAMA Bright limits: total count rate per image 97913.1 exceeds limit for irregularly-variable sources 40 percent of the bright limit 200000 counts per second
WARNING MESSAGE: Buffer time 20.4263 is less than minimum 99 seconds.
Table of Source and Noise Counts per Pixel
| Detailed Information | Count rate | Total counts | Associated noise |
| (counts/s) | (counts) | (counts) | |
| Counts (box 7 pixels high) | (1 pix x 7 pix) | (2 pix resel x 7 pix) | |
| Source | 1.523 | 8,528.99 | 92.35 |
| Background | 0.011 | 58.80 | 7.67 |
| Sky | 9.899e-11 | 5.54e-07 | 7.45e-04 |
| Dark Current | 0.011 | 58.80 | 7.67 |
| Total in selected region | 1.534 | 8,587.79 | 93.89 |
| Brightest Pixel (single exposure) (at 2679.65 Å) | 1.732 | 4,848.47 | |
| Count rate entire detector | 97,913.126 | ||
| Buffer Time (sec) | 20.43 | ||
| For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details. | |||
|
|
|||
| Global Count Rates | |||
| Source only | 85,483.834 | 239,354,733.811 | |
| Background (sky+dark) | 1,572.865 | 4,404,022.32 | |
| Encircled energy fraction | 0.93 | ||
| Instrument name: | STIS |
| Mode: | spectroscopic |
| Detector: | NUVMAMA |
| Central Wavelength: | 2812 |
| Grating: | [E230H] R ~ 114000 |
| Aperture: | 31X0.05NDA |
| Target: [point source] | |
| Spectrum: | Kurucz Models A5V 8200 4.3 |
| Extinction E(B-V): | None |
| Normalization: | Renormalized to vegamag = 3.86 in filter Johnson/V |
| Redshift: | None |
| Emission Lines: | None |
| Selected background: | |
| Sky Background: | |
| Level: |
Table of Source and Noise Counts per Pixel
These results were computed using: ETC version 26.1