ETC Request ID: STIS.sp.1152523

Requested Signal/Noise Ratio = 10.000 at wavelength 2800.00 Å (per resolution element)

gives: Time = 432.0712 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.125 108.39 10.41
    Background 0.011 9.09 3.02
        Sky 2.270e-05 0.02 0.14
        Dark Current 0.011 9.07 3.01
Total in selected region 0.136 117.48 10.84
Brightest Pixel (single exposure) (at 2796.80 Å) 0.143 61.63
Count rate entire detector 1,605.389

Buffer Time (sec) 1,245.80
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 15.120 6,533.012
    Background (sky+dark) 1,590.269 687,109.44

Encircled energy fraction 0.87


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength:
Grating: [G230L] R ~ 500
Aperture: 52X2


Target: [point source]
Spectrum: User uploaded spectrum: muscles_M3.5.csv
Extinction E(B-V): None
Normalization: Renormalized to abmag = 21.39 in filter Galex/NUV
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2