ETC Request ID: STIS.sp.1046409

Requested Signal/Noise Ratio = 10.000 at wavelength 1393.00 Å (per resolution element)

gives: Time = 1,336.5864 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.038 102.73 10.14
    Background 0.001 2.81 1.68
        Sky 2.339e-12 6.25e-09 7.91e-05
        Dark Current 0.001 2.81 1.68
Total in selected region 0.039 105.54 10.27
Brightest Pixel (single exposure) (at 1548.90 Å) 0.042 55.71
Count rate entire detector 270.926

Buffer Time (sec) 7,382.09
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 0.488 651.928
    Background (sky+dark) 270.438 361,464.19

Encircled energy fraction 0.82


Instrument name: STIS
Mode: spectroscopic
Detector: FUVMAMA
Central Wavelength:
Grating: [G140L] R ~ 1000
Aperture: 52X0.2
Glow region: low


Target: [point source]
Spectrum: Empty
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines:
Line at Center 1393.0 Å    FWHM 0.08 Å   Flux 2.1e-15 Fλ
Line at Center 1549.0 Å    FWHM 0.08 Å   Flux 1.67e-14 Fλ


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2