ETC Request ID: STIS.sp.1046083

Requested Signal/Noise Ratio = 10.000 at wavelength 2800.00 Å (per resolution element)

gives: Time = 68.1805 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.744 101.41 10.07
    Background 0.011 1.43 1.20
        Sky 9.870e-07 1.35e-04 0.01
        Dark Current 0.011 1.43 1.20
Total in selected region 0.754 102.84 10.14
Brightest Pixel (single exposure) (at 2796.80 Å) 0.639 43.55
Count rate entire detector 1,910.081

Buffer Time (sec) 1,047.08
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 335.474 22,872.807
    Background (sky+dark) 1,574.606 107,357.42

Encircled energy fraction 0.87


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength:
Grating: [G230L] R ~ 500
Aperture: 52X0.2


Target: [point source]
Spectrum: Black body at 3550.0K
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 12.342 in filter Johnson/U
Redshift: None
Emission Lines:
Line at Center 2796.0 Å    FWHM 1.5 Å   Flux 3.3e-14 Fλ
Line at Center 2804.0 Å    FWHM 1.5 Å   Flux 2.5e-14 Fλ


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2