ETC Request ID: STIS.sp.1035939

Exposure time (seconds) = 1.0000 at wavelength 9500.00 Å

gives: SNR = 41.8355 (per resolution element)

gives: Time to Saturation (for a single exposure) = 121.27 seconds

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: "Electrons per pixel due to background (0.009) is less than the recommended threshold of 20 electrons to avoid poor charge transfer efficiency (CTE). We suggest you consider CTE mitigation strategies described in the STIS Instrument Handbook."


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(e-/s) (e-) (e-)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 1,445.199 2,890.40 53.76
    Background 0.126 0.25 0.50
        Sky 4.701e-05 9.40e-05 9.70e-03
        Dark Current 0.126 0.25 0.50
    Read Out 43.39
Total in selected region 1,445.325 2,890.65 69.09
Brightest Pixel (single exposure) (at 9050.55 Å) 989.528 494.76

Global Count Rates
    Source only 2,605,964.147 2,605,964.147
    Background (sky+dark) 18,882.328 18,882.33

Encircled energy fraction 0.68


Instrument name: STIS
Mode: spectroscopic
Detector: CCD
Central Wavelength: 9336
Grating: [G750M] R ~ 5000
Aperture: 52X0.1
Gain: 4.0
# Frames: 2
Binning: dispersion: 1, spatial: 1
Dark: medium


Target: [point source]
Spectrum: Bruzual Synthetic Stellar Spectra B1 III
Extinction E(B-V): Milky Way Diffuse (Rv=3.1) = 0.03 applied before normalization
Normalization: Renormalized to vegamag = 5.3 in filter Johnson/J
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2