ETC Request ID: STIS.im.1013929

Exposure time (seconds) = 0.1000

gives: SNR = 1,396.9187

gives: Time to Saturation (for a single exposure) = 0.02 seconds

gives: Optimum SNR = 1,562.6895

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: CCD Full Well limits: total counts per native pixel 536484 exceeds bright limit 120000 for selected gain

WARNING MESSAGE: "Electrons per pixel due to background (0.01) is less than the recommended threshold of 20 electrons to avoid poor charge transfer efficiency (CTE). We suggest you consider CTE mitigation strategies described in the STIS Instrument Handbook."



Plots


Detailed Information Count rate Total counts Associated noise
(e-/s) (e-) (e-)
Counts (circle with radius 0.212 arcsec)
    Source 19,552,075.032 1,955,207.50 1,398.29
    Background 5.719 0.57 0.76
        Sky 4.693 0.47 0.69
        Dark Current 1.026 0.10 0.32
    Read Out 61.91
Total in selected region 19,552,080.751 1,955,208.08 1,399.66
Brightest Pixel (single exposure) 5,364,843.086 536,484.31

Global Count Rates
    Source only 24,440,093.790 2,444,009.379
    Background (sky+dark) 106,019.251 10,601.93

Background per unit area
    Sky Background (arcsec-2) 33.243 3.324
    Dark Current (arcsec-2) 7.200 0.720

Extraction region
circle with radius 0.212 arcsec
    Effective Sky Area (pixels) 56.46
    Fraction of flux 0.80
    Fraction of flux in brightest pixel 0.22
Effective Wavelength 6289.07 Å


Instrument name: STIS
Mode: imaging
Detector: CCD
Aperture: 50CCD
Gain: 4.0
# Frames: 1
Binning: 1
Dark: medium


Target: [point source]
Spectrum: Kurucz Models G2V 5860 4.4
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 7.572 in filter Johnson/V
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:


Plots

These results were computed using: ETC version 25.2