ETC Request ID: STIS.ta.1013682

Requested Signal/Noise Ratio = 40.000

gives: Time = 0.0449 seconds

gives: Time to Saturation (for a single exposure) = 7.98 seconds

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: Result of the calculation 0.0449105 is less than the minimum exposure time for this detector (0.1)



Plots


Detailed Information Count rate Total counts Associated noise
(e-/s) (e-) (e-)
Counts (box of 3 x 3 pixels)
    Source 46,051.044 2,068.17 45.48
    Background 0.164 7.35e-03 0.09
        Sky 0.002 7.04e-05 8.39e-03
        Dark Current 0.162 7.28e-03 0.09
    Read Out 24.60
Total in selected region 46,051.207 2,068.18 51.70
Brightest Pixel (single exposure) 15,044.318 675.65

Global Count Rates
    Source only 92,102.088 4,136.350
    Background (sky+dark) 18,917.910 849.61

Background per unit area
    Sky Background (arcsec-2) 0.070 0.003
    Dark Current (arcsec-2) 7.200 0.323

Extraction region
box of 3 x 3 pixels
    Effective Sky Area (pixels) 9.00
    Fraction of flux 0.50
    Fraction of flux in brightest pixel 0.16
Effective Wavelength 7896.12 Å


Instrument name: STIS
Mode: Target Acquisition
Detector: CCD
Acquisition Mode: ACQ
Aperture: F25ND3
Gain: 4.0
# Frames: 1
Binning: 1
Dark: medium


Target: [point source]
Spectrum: Castelli-Kurucz Models M2V 3500 4.5
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 10.03 in filter Johnson/U
Redshift: None
Emission Lines:
Line at Center 1215.14 Å    FWHM 0.5 Å   Flux 4.1e-12 Fλ


Selected background:
  Sky Background:
    Level:


Plots

These results were computed using: ETC version 25.2