ETC Request ID: STIS.sp.1012360

Exposure time (seconds) = 1,035.0000 at wavelength 2200.00 Å

gives: SNR = 14.1916 (per resolution element)


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.107 221.19 14.87
    Background 0.011 21.74 4.66
        Sky 5.554e-07 1.15e-03 0.03
        Dark Current 0.011 21.74 4.66
Total in selected region 0.117 242.93 15.59
Brightest Pixel (single exposure) (at 2800.00 Å) 1.079 1,116.70
Count rate entire detector 1,796.175

Buffer Time (sec) 1,113.48
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 221.569 229,323.505
    Background (sky+dark) 1,574.606 1,629,717.65

Encircled energy fraction 0.85


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength:
Grating: [G230L] R ~ 500
Aperture: 52X0.2


Target: [point source]
Spectrum: User uploaded spectrum: m81fos.txt
Extinction E(B-V): None
Normalization: None
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2