ETC Request ID: STIS.sp.1011626

Requested Signal/Noise Ratio = 50.000 at wavelength 2796.00 Å (per resolution element)

gives: Time = 1,521.5140 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.854 2,598.38 50.97
    Background 0.011 31.95 5.65
        Sky 1.039e-09 3.16e-06 1.78e-03
        Dark Current 0.011 31.95 5.65
Total in selected region 0.864 2,630.33 51.97
Brightest Pixel (single exposure) (at 2796.30 Å) 0.608 925.69
Count rate entire detector 11,068.942

Buffer Time (sec) 180.69
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 8,123.249 12,359,637.052
    Background (sky+dark) 1,572.864 2,393,134.67

Encircled energy fraction 0.93


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength: 2713
Grating: [E230H] R ~ 114000
Aperture: 0.2X0.09


Target: [point source]
Spectrum: Kurucz Models G2V 5860 4.4
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 6.17 in filter Johnson/V
Redshift: None
Emission Lines:
Line at Center 2796.3 Å    FWHM 0.6 Å   Flux 4.42e-12 Fλ


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2