ETC Request ID: STIS.sp.1011399

Requested Signal/Noise Ratio = 50.000 at wavelength 2796.00 Å (per resolution element)

gives: Time = 1,362.0345 seconds

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: Buffer time 66.9665 is less than minimum 99 seconds.


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.953 2,595.19 50.94
    Background 0.011 28.60 5.35
        Sky 1.039e-09 2.83e-06 1.68e-03
        Dark Current 0.011 28.60 5.35
Total in selected region 0.963 2,623.79 51.90
Brightest Pixel (single exposure) (at 2653.66 Å) 0.756 1,030.13
Count rate entire detector 29,865.667

Buffer Time (sec) 66.97
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 24,202.573 32,964,739.212
    Background (sky+dark) 1,572.864 2,142,295.05

Encircled energy fraction 0.93


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength: 2713
Grating: [E230H] R ~ 114000
Aperture: 0.2X0.09


Target: [point source]
Spectrum: Kurucz Models F8V 6200 4.4
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 5.4 in filter Johnson/V
Redshift: None
Emission Lines:
Line at Center 2796.3 Å    FWHM 0.6 Å   Flux 4.02e-12 Fλ


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2