ETC Request ID: STIS.sp.1010281

Requested Signal/Noise Ratio = 5.000 at wavelength 2850.00 Å (per resolution element)

gives: Time = 572.1528 seconds


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(counts/s) (counts) (counts)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 0.030 33.87 5.82
    Background 0.011 12.02 3.47
        Sky 1.875e-06 2.15e-03 0.05
        Dark Current 0.011 12.02 3.47
Total in selected region 0.040 45.89 6.77
Brightest Pixel (single exposure) (at 2796.80 Å) 0.253 144.62
Count rate entire detector 1,589.702

Buffer Time (sec) 1,258.10
For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details.

Global Count Rates
    Source only 15.096 8,637.132
    Background (sky+dark) 1,574.606 900,915.48

Encircled energy fraction 0.87


Instrument name: STIS
Mode: spectroscopic
Detector: NUVMAMA
Central Wavelength:
Grating: [G230L] R ~ 500
Aperture: 52X0.2


Target: [point source]
Spectrum: Black body at 3300.0K
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 14.834 in filter Johnson/B
Redshift: None
Emission Lines:
Line at Center 2797.2 Å    FWHM 1.73 Å   Flux 2e-14 Fλ
Line at Center 2804.0 Å    FWHM 1.73 Å   Flux 1.5e-14 Fλ


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2