ETC Request ID: STIS.sp.1009275

Exposure time (seconds) = 0.1000 at wavelength 3680.00 Å

gives: SNR = 1.8170 (per resolution element)

gives: Time to Saturation (for a single exposure) = 624.24 seconds

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: Result of the calculation 0.05 is less than the minimum exposure time for this detector (0.1)

WARNING MESSAGE: "Electrons per pixel due to background (0.0009) is less than the recommended threshold of 20 electrons to avoid poor charge transfer efficiency (CTE). We suggest you consider CTE mitigation strategies described in the STIS Instrument Handbook."


Table of Source and Noise Counts per Pixel


Plots


Detailed Information Count rate Total counts Associated noise
(e-/s) (e-) (e-)
Counts (box 7 pixels high) (1 pix x 7 pix) (2 pix resel x 7 pix)
    Source 402.554 80.51 8.97
    Background 0.126 0.03 0.16
        Sky 1.731e-08 3.46e-09 5.88e-05
        Dark Current 0.126 0.03 0.16
    Read Out 43.39
Total in selected region 402.680 80.54 44.31
Brightest Pixel (single exposure) (at 3780.04 Å) 192.234 9.61

Global Count Rates
    Source only 375,515.122 37,551.512
    Background (sky+dark) 18,874.368 1,887.44

Encircled energy fraction 0.94


Instrument name: STIS
Mode: spectroscopic
Detector: CCD
Central Wavelength: 3680
Grating: [G430M] R ~ 6000
Aperture: 0.2X0.05ND
Gain: 4.0
# Frames: 2
Binning: dispersion: 1, spatial: 1
Dark: medium


Target: [point source]
Spectrum: Pickles Models K3III 4365.16K
Extinction E(B-V): None
Normalization: Renormalized to vegamag = -0.05 in filter Johnson/V
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:

Table of Source and Noise Counts per Pixel


Plots

These results were computed using: ETC version 25.2