ETC Request ID: STIS.sp.1005543
Exposure time (seconds) = 200.0000 at wavelength 2630.00 Å
gives: SNR = 40.9495 (per resolution element)
Exposure time calculation HAD WARNINGS.
WARNING MESSAGE: MAMA Bright limits: total count rate per image 140898 exceeds limit for irregularly-variable sources 40 percent of the bright limit 200000 counts per second
WARNING MESSAGE: Buffer time 14.1947 is less than minimum 99 seconds.
Table of Source and Noise Counts per Pixel
| Detailed Information | Count rate | Total counts | Associated noise |
| (counts/s) | (counts) | (counts) | |
| Counts (box 7 pixels high) | (1 pix x 7 pix) | (2 pix resel x 7 pix) | |
| Source | 4.366 | 1,746.30 | 41.79 |
| Background | 0.011 | 4.20 | 2.05 |
| Sky | 1.442e-10 | 5.77e-08 | 2.40e-04 |
| Dark Current | 0.011 | 4.20 | 2.05 |
| Total in selected region | 4.376 | 1,750.50 | 42.65 |
| Brightest Pixel (single exposure) (at 2644.68 Å) | 2.116 | 423.12 | |
| Count rate entire detector | 140,897.945 | ||
| Buffer Time (sec) | 14.19 | ||
| For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details. | |||
|
|
|||
| Global Count Rates | |||
| Source only | 111,193.271 | 22,238,654.132 | |
| Background (sky+dark) | 1,572.864 | 314,572.84 | |
| Encircled energy fraction | 0.93 | ||
| Instrument name: | STIS |
| Mode: | spectroscopic |
| Detector: | NUVMAMA |
| Central Wavelength: | 2513 |
| Grating: | [E230H] R ~ 114000 |
| Aperture: | 0.1X0.03 |
| Target: [point source] | |
| Spectrum: | Castelli-Kurucz Models A3V 8750 4.0 |
| Extinction E(B-V): | None |
| Normalization: | Renormalized to vegamag = 4.45 in filter Johnson/V |
| Redshift: | None |
| Emission Lines: | None |
| Selected background: | |
| Sky Background: | |
| Level: |
Table of Source and Noise Counts per Pixel
These results were computed using: ETC version 25.2