ETC Request ID: STIS.ta.1003611

Requested Signal/Noise Ratio = 40.000

gives: Time = 0.0152 seconds

gives: Time to Saturation (for a single exposure) = 2.41 seconds

Exposure time calculation HAD WARNINGS.

WARNING MESSAGE: Result of the calculation 0.0152261 is less than the minimum exposure time for this detector (0.1)



Plots


Detailed Information Count rate Total counts Associated noise
(e-/s) (e-) (e-)
Counts (box of 3 x 3 pixels)
    Source 135,830.848 2,068.18 45.48
    Background 0.597 9.09e-03 0.10
        Sky 0.435 6.62e-03 0.08
        Dark Current 0.162 2.47e-03 0.05
    Read Out 24.60
Total in selected region 135,831.445 2,068.19 51.70
Brightest Pixel (single exposure) 49,881.257 759.50

Global Count Rates
    Source only 271,661.697 4,136.352
    Background (sky+dark) 46,585.728 709.32

Background per unit area
    Sky Background (arcsec-2) 19.330 0.294
    Dark Current (arcsec-2) 7.200 0.110

Extraction region
box of 3 x 3 pixels
    Effective Sky Area (pixels) 9.00
    Fraction of flux 0.50
    Fraction of flux in brightest pixel 0.18
Effective Wavelength 7344.02 Å


Instrument name: STIS
Mode: Target Acquisition
Detector: CCD
Acquisition Mode: ACQ
Aperture: F28X50LP
Gain: 4.0
# Frames: 1
Binning: 1
Dark: medium


Target: [point source]
Spectrum: Kurucz Models K4V 4560 4.5
Extinction E(B-V): None
Normalization: Renormalized to vegamag = 12.2 in filter Johnson/V
Redshift: None
Emission Lines: None


Selected background:
  Sky Background:
    Level:


Plots

These results were computed using: ETC version 25.2