ETC Request ID: STIS.sp.1003510
Exposure time (seconds) = 7,875.0000 at wavelength 1400.00 Å
gives: SNR = 9.9915 (per resolution element)
Table of Source and Noise Counts per Pixel
| Detailed Information | Count rate | Total counts | Associated noise |
| (counts/s) | (counts) | (counts) | |
| Counts (box 7 pixels high) | (1 pix x 7 pix) | (2 pix resel x 7 pix) | |
| Source | 0.007 | 114.28 | 10.69 |
| Background | 0.001 | 16.54 | 4.07 |
| Sky | 2.445e-12 | 3.85e-08 | 1.96e-04 |
| Dark Current | 0.001 | 16.54 | 4.07 |
| Total in selected region | 0.008 | 130.81 | 11.44 |
| Brightest Pixel (single exposure) (at 1217.70 Å) | 0.013 | 104.22 | |
| Count rate entire detector | 276.574 | ||
| Buffer Time (sec) | 7,231.35 | ||
| For APT purposes, the recommended buffer time should be 4/5 of the buffer time calculated above. Please refer to the STIS Instrument Handbook for more details. | |||
|
|
|||
| Global Count Rates | |||
| Source only | 6.135 | 48,315.227 | |
| Background (sky+dark) | 270.438 | 2,129,701.84 | |
| Encircled energy fraction | 0.82 | ||
| Instrument name: | STIS |
| Mode: | spectroscopic |
| Detector: | FUVMAMA |
| Central Wavelength: | |
| Grating: | [G140L] R ~ 1000 |
| Aperture: | 52X0.2 |
| Glow region: | low |
| Target: [point source] | |
| Spectrum: | Black body at 30000.0K |
| Extinction E(B-V): | None |
| Normalization: | Renormalized to abmag = 22.0 in filter Sloan/R |
| Redshift: | None |
| Emission Lines: | None |
| Selected background: | |
| Sky Background: | |
| Level: |
Table of Source and Noise Counts per Pixel
These results were computed using: ETC version 25.2