ETC Request ID: STIS.ta.1003285
Requested Signal/Noise Ratio = 40.000
gives: Time = 0.0991 seconds
gives: Time to Saturation (for a single exposure) = 14.39 seconds
Exposure time calculation HAD WARNINGS.
WARNING MESSAGE: Result of the calculation 0.0990824 is less than the minimum exposure time for this detector (0.1)
WARNING MESSAGE: Partial overlap between instrument throughput band and target spectrum. Please doublecheck the wavelength range covered by the selected spectrum, and the instrument documentation for the selected filter.
| Detailed Information | Count rate | Total counts | Associated noise |
| (e-/s) | (e-) | (e-) | |
| Counts (box of 3 x 3 pixels) | |||
| Source | 20,873.617 | 2,068.21 | 45.48 |
| Background | 0.597 | 0.06 | 0.24 |
| Sky | 0.435 | 0.04 | 0.21 |
| Dark Current | 0.162 | 0.02 | 0.13 |
| Read Out | 24.60 | ||
| Total in selected region | 20,874.214 | 2,068.27 | 51.71 |
| Brightest Pixel (single exposure) | 8,339.437 | 826.29 | |
|
|
|||
| Global Count Rates | |||
| Source only | 41,747.235 | 4,136.415 | |
| Background (sky+dark) | 46,585.728 | 4,615.82 | |
|
|
|||
| Background per unit area | |||
| Sky Background (arcsec-2) | 19.330 | 1.915 | |
| Dark Current (arcsec-2) | 7.200 | 0.713 | |
| Extraction region | |||
| box of 3 x 3 pixels | |||
| Effective Sky Area (pixels) | 9.00 | ||
| Fraction of flux | 0.50 | ||
| Fraction of flux in brightest pixel | 0.20 | ||
| Effective Wavelength | 6895.59 Å | ||
| Instrument name: | STIS |
| Mode: | Target Acquisition |
| Detector: | CCD |
| Acquisition Mode: | ACQ |
| Aperture: | F28X50LP |
| Gain: | 4.0 |
| # Frames: | 1 |
| Binning: | 1 |
| Dark: | medium |
| Target: [point source] | |
| Spectrum: | User uploaded spectrum: SN2015F_full_20150326.dat |
| Extinction E(B-V): | None |
| Normalization: | Renormalized to vegamag = 13.5 in filter Johnson/V |
| Redshift: | None |
| Emission Lines: | None |
| Selected background: | |
| Sky Background: | |
| Level: |
These results were computed using: ETC version 25.2